| NEOTHERM
: Oil / Gas / Solid Fuel Fired fully automatic thermic fluid |
|
| Salient
Features :- |
| 1)
Fully automatic |
| 2)
Easy operation & fail proof system. |
| 3)
Outside the purview of IBR. |
| 4)
Packaged models. |
| 5)
100% depreciation in the first year. |
| 6)
Record efficiency. |
| Neotherm
is an oil/solid fuel fired thermic fluid heater in vertical / horizontal
design having four heat transfer to ensure optimum efficiency. It
ensures that maximum of its heating surface is exposed to radiant
heat there by ensuring excellent thermal efficiency. |
| Efficient
combustion, forced circulation, liberal heat transfer areas &
large furnace volume ensures over all efficiency of 88%± 1%
on N.C.V.NEOTHERM
is available in wide range of capacities from 50,000 Kcals/hr to 10,00,000
Kcals/hr at maximum operating temperature of 300°C. |
|
Technical Specifications :
| Details |
Unit |
NT-50 |
NT-100 |
NT-200 |
NT-300 |
NT-400 |
NT-600 |
NT-1000 |
Operating
Parameters
Capacity |
KCals/Hr. |
50000 |
100000 |
200000 |
300000 |
400000 |
600000 |
1000000 |
| Max.
Operating Temp. (At the outlet of the unit) |
0C |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
Fuel
Oil Consumption At full load LDO
FO |
Kgs/Hr
Kgs/Hr. |
5.4
-- |
10.8
-- |
21.5
22.6 |
32.4
33.9 |
42.9
45 |
64.3
67.5 |
107.2
112.5 |
| Efficiency
(GCV) |
% |
86+/-1 |
86+/-1 |
86+/-1 |
86+/-1 |
86+/-1 |
86+/-1 |
86+/-1 |
| Burner
Control |
--------------------------------ON-OFF------------------ |
| Electric
Supply |
AC-3 Phase -
415V +/- 6%; 50 Hz, 4 Wire |
| Connected
Elec. Load |
|
| Thermic
Fluid Pump Motor |
(HP) |
3 |
5 |
7.5 |
10 |
10 |
20 |
25 |
| Blower
Motor |
(HP) |
1 |
1.5 |
2 |
2 |
3 |
5 |
10 |
| Fuel
Oil Preheater (For F.O. Fired Unit Only) |
KW |
-- |
-- |
3 |
4.5 |
4.5 |
6 |
9 |
Total
Elec. Load
For LDO Fired Units
For FO Fired Units |
HP
HP + KW |
4
-- |
6.5
-- |
9.5
9.5+3 |
12
12+4.5 |
13
13+4.5 |
25
25+6 |
35
35+9 |
| Overall
Dimensions |
|
|
|
|
|
|
|
|
| Length |
(Mts) |
2 |
3 |
4 |
4 |
4 |
4 |
4 |
| Width |
(Mts) |
2 |
3 |
4 |
4 |
4 |
5 |
5 |
| Clear
Height |
(Mts) |
2.5 |
2.5 |
4 |
5 |
5 |
5 |
6 |
| Fuel
Gas Outlet |
(MM) |
250 |
250 |
250 |
300 |
300 |
400 |
500 |
| Cross
Dry Weight |
(Kgs) |
1000 |
1350 |
1750 |
2400 |
2900 |
3500 |
5250 |
* Designs and Specifications
subject to changes due to constant research and development
* The efficiency is guaranteed on the test bay with commercially
clean internal and external
heat transfer surfaces.
" NEOTHERM-C"
SOLID FUEL FIRED 3-PASS THERMIC FLUID HEATER
Technical
Specification
| PARAMETERS |
UNIT |
NTC
: 200 |
NTC
: 300 |
NTC
: 400 |
NTC
: 600 |
NTC
: 1000 |
| Heat
Output |
Kcal/hr |
2,00,000 |
3,00,000 |
4,00,000 |
6,00,000 |
10,00,000 |
| Outlet
temperature (max) |
0C |
300 |
300 |
300 |
300 |
300 |
Temp
rise ( T) in
the heater |
0C |
25 |
25 |
25 |
25 |
25 |
| Pressure
at heater outlet |
Kg/cm2 |
2.2 |
2.2 |
2.5 |
2.5 |
2.5 |
| Flue
gas duct diameter |
mm |
250 |
300 |
300 |
350 |
450 |
| Inlet
/ Outlet connection of heater |
mm |
50 |
50 |
65 |
65 |
100 |
|
FUEL
CONSUMPTION |
| Coal |
Kgs/hr |
64 |
96 |
128 |
192 |
320 |
| Wood |
Kgs/hr |
87 |
130 |
174 |
260 |
435 |
| ELECTRICAL
LOAD |
Thermic
Fluid
Pump Motor |
Kw |
5.5 |
5.5 |
7.5 |
11.0 |
15 |
| I.D.
fan motor + F.D. fan motor |
Kw |
1.5+0.375 |
2.2+0.75 |
2.2+0.75 |
3.7+1.5 |
5+2.2 |
| Total
Connected Load |
Kw |
7.375 |
8.45 |
10.45 |
16.2 |
22.2 |
Non-IBR four pass fully stream
generating boiler in oil fired
Oil / Gas / Solid Fuel Fired fully automatic
thermic fluid
Fully automatic hot air generators in oil fired
design for drying applications
Fully
automatic oil / gas fired (Pressurized / Non - Pressurized) Hot Water
Generators
|