Thermic fluid heaters, Fuel fired Thermic fluid heaters, Oil fired Thermic fluid heaters, Solid fuel Thermic fluid heaters, India
Neotherm is an oil/solid fuel fired thermic fluid heater in vertical / horizontal design having four heat transfer to ensure optimum efficiency. The main speciality of our products is maximum of its heating surface is exposed to radiant heat there by ensuring excellent thermal efficiency.
Efficient combustion, forced circulation, liberal heat transfer areas & large furnace volume ensures over all efficiency of 88%± 1% on N.C.V.NEOTHERM is available in wide range of capacities from 50,000 Kcals/hr to 15,00,000 Kcals/hr at maximum operating temperature of 300°C.
Details | Unit | NT-50 | NT-100 | NT-200 | NT-300 | NT-400 | NT-600 | NT-1000 | NT-1500 |
Operating Parameters |
|||||||||
Capacity | KCals/Hr. | 50000 | 100000 | 200000 | 300000 | 400000 | 600000 | 1000000 | 1500000 |
Max. Operating Temp. (At the outlet of the unit) | 0C | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 |
Fuel
Oil Consumption At full load LDO FO |
Kgs/Hr Kgs/Hr. |
5.4 -- |
10.8 -- |
21.5 22.6 |
32.4 33.9 |
42.9 45 |
64.3 67.5 |
107.2 112.5 |
160.80 168.75 |
Efficiency (GCV) | % | 87+/-1 | 87+/-1 | 87+/-1 | 87+/-1 | 87+/-1 | 87+/-1 | 87+/-1 | 87+/-1 |
Burner Control |
------------------------------ON---OFF------------------------------TWO STAGE |
||||||||
Electric Supply | AC-3 Phase - 415V +/- 6%; 50 Hz, 4 Wire | ||||||||
Connected Elec. Load | |||||||||
Thermic Fluid Pump Motor | (HP) | 3 | 5 | 7.5 | 10 | 10 | 15 | 20 | 30 |
Blower Motor | (HP) | 1 | 1 | 1.5 | 2 | 3 | 5 | 10 | 10 |
Fuel Pump Motor | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 1.0 | 1.0 | |
Fuel Oil Preheater (For FO Fired Units Only) | KW | -- | -- | 4.5 | 6.0 | 6.0 | 9.0 | 12 | 15 |
Total
Elec. Load For LDO Fired Units FO Fired Units |
HP HP + KW |
4.5 -- |
6.5 -- |
9.5 9.5+4.5 |
12.5 12.5+6 |
13.5 13.5+6 |
20.5 20.5+9 |
31 31+12 |
41 41+15 |
Overall Dimensions | |||||||||
Length | (Mts) | 2 | 3 | 4 | 4 | 4 | 4 | 4 | 6 |
Width | (Mts) | 2 | 3 | 4 | 4 | 4 | 5 | 5 | 6 |
Clear Height | (Mts) | 2.5 | 2.5 | 4 | 5 | 5 | 5 | 6 | 8 |
Fuel Gas Outlet | (MM) | 200 | 200 | 250 | 250 | 300 | 350 | 500 | 600 |
Gross Dry Weight | (Kgs) | 1000 | 1350 | 1750 | 2400 | 2900 | 3500 | 5250 | 6500 |
PARAMETERS | UNIT | NTC : 200 | NTC : 300 | NTC : 400 | NTC : 600 | NTC : 1000 | |
Heat Output | Kcal/hr | 2,00,000 | 3,00,000 | 4,00,000 | 6,00,000 | 10,00,000 | |
Outlet temperature (max) | °C | 300 | 300 | 300 | 300 | 300 | |
Temp rise ( T) in the heater | °C | 25 | 25 | 25 | 25 | 25 | |
Pressure at heater outlet | Kg/cm² | 2.2 | 2.2 | 2.5 | 2.5 | 2.5 | |
Flue gas duct diameter | mm | 250 | 300 | 300 | 350 | 450 | |
Inlet / Outlet connection of heater | mm | 50 | 50 | 65 | 65 | 100 | |
FUEL CONSUMPTION |
|||||||
Coal | Kgs/hr | 64 | 96 | 128 | 192 | 320 | |
Wood | Kgs/hr | 87 | 130 | 174 | 260 | 435 | |
ELECTRICAL LOAD | |||||||
Thermic Fluid Pump Motor | Kw | 5.5 | 5.5 | 7.5 | 11.0 | 15 | |
I.D. fan motor + F.D. fan motor | Kw | 1.5+0.375 | 2.2+0.75 | 2.2+0.75 | 3.7+1.5 | 5+2.2 | |
Total Connected Load | Kw | 7.375 | 8.45 | 10.45 | 16.2 | 22.2 |